ABOUT US

Our development agency is committed to providing you the best service.

OUR TEAM

The awesome people behind our brand ... and their life motto.

  • Neila Jovan

    Head Hunter

    I long for the raised voice, the howl of rage or love.

  • Mathew McNalis

    Marketing CEO

    Contented with little, yet wishing for much more.

  • Michael Duo

    Developer

    If anything is worth doing, it's worth overdoing.

OUR SKILLS

We pride ourselves with strong, flexible and top notch skills.

Marketing

Development 90%
Design 80%
Marketing 70%

Websites

Development 90%
Design 80%
Marketing 70%

PR

Development 90%
Design 80%
Marketing 70%

ACHIEVEMENTS

We help our clients integrate, analyze, and use their data to improve their business.

150

GREAT PROJECTS

300

HAPPY CLIENTS

650

COFFEES DRUNK

1568

FACEBOOK LIKES

STRATEGY & CREATIVITY

Phasellus iaculis dolor nec urna nullam. Vivamus mattis blandit porttitor nullam.

PORTFOLIO

We pride ourselves on bringing a fresh perspective and effective marketing to each project.

  • Cable Coating Firestop

    Cable Coating Firestop


    Metacaulk® Industrial  Cable Coating telah secara khusus dirancang untuk digunakan untuk melindungi berbagai jenis kabel dalam industri dan bangunan yang rawan terhadap kebakaran atau terkena bahan yang membayakan kabel.
    Metacaulk® Industrial  Cable Coating menggunakan bahan berbasis air, siap langsung dipakai dan coating yang tahan terhadap berbagai kondisi yang disesuaikan dengan standard Factory Mutual (FM).
    Metacaulk® Industrial  Cable Coating dapat menahan api dan dirancang untuk mencegah penyebaran kebakaran baik secara  vertikal atau horizontal pada susunan kabel komunikasi maupun kabel listrik.. Metacaulk® Industrial  Cable Coating cocok untuk aplikasi interior atau eksterior dan kedua UV dan tahan cuaca. (Metacaulk® Industrial  Cable Coating juga hampir tidak terpengaruh oleh paparan langsung radiasi matahari.).
    Penggunaan Metacaulk® Industrial  Cable Coating tidak diperlukan bahan tambahan apapun karena bisa langsung dipakai. Untuk hasil yang maksimal gunakan dengan 2 lapis coating.
    Metacaulk® Industri Kabel Coating bebas dari bahan halogen dan tidak mengandung solvent, plastik, asbes, atau serat anorganik berbahaya lainnya. Metacaulk® Industrial  Cable Coating memiliki bau yang rendah, kompatibel dan rekat dengan bahan lapisan kabel apapun.
    Formulasi Metacaulk® Industri Kabel Coating telah digunakan oleh peralatan utama dan industri selama lebih dari 25 tahun dan dianggap oleh beberapa orang untuk menjadi standard dalam industri.
    Fitur dari Metacaulk® Industri Kabel Coating :
    * Melindungi kabel dari api dan kebakaran
    * Berbasis Air  & Bau yang rendah
    * Bebas Asbes
    * Fleksibel dan Tahan Lama
    * Tahan terhadap Air dan Cuaca buruk
    * Tahan terhadap Ultra Violet (UV)
    * Tidak ada berdampak mengurangi kualitas kabel
    Color :      White/Gray
    Dry coverage :    18.5 ft²/gal (0.45m²/L)*
    Flash Point:     >212ºF/100ºC
    Ampacity reduction   None**
    Flame Spread (ASTM E84)  15
    Smoke Developed (ASTM E84)  35
    Vapor permeability (ASTM E96) 9.32 Perms
    *Based on 0.0635 in. (63 mils or 1.6mm)
    dry coating thickness
    **Based on 0.125 in. (3.2mm) dry
    coating thickness

  • Metacaulk FireStop Product

    Metacaulk FireStop Product


    Metacaulk Firestop Product merupakan produk yang dirancang khusus untuk memberikan perlindungan terhadap dampak saat kebakaran agar tidak menyebar ke lokasi lainnya.
    Firestop product bersifat pasif untuk menghentikan api & asap saat kebakaran serta mengurangi resiko kerusakan yang meluas akibat dampak kebakaran.
    Karena dampak kebakaran pada sebuah ruangan/lokasi berpotensi merambat ke tempat lain lewat kabel atau instalasi pipa & sambungan.

    Metacaulk firestop product dikembangkan dengan standard internasional untuk penanggulangan kebakaran dan sudah terdaftar resmi sebagai anggota International Firestop Council 


    Berikut standard mutu material & lisensi international produk Metacaulk :

    UL 263: Fire Tests of Building Construction and Materials
    UL 723: Surface Burning Characteristics of Building Materials
    UL 1479: Fire Tests of Through Penetration Fire Stops
    UL 2079: Tests for Fire Resistance of Building Joint Systems
    Factory Mutual Approval Standard for Firestopping 4990
    ASTM E814: Through-Penetration Firestops
    ASTM E1966: Fire Resistive Joint Systems
    ASTM E84: Surface Burning Characteristics of Building Materials
    ASTM E2307: Fire Endurance of Perimeter Fire Barrier Systems
    ASTM E119: Methods of Fire Tests of Building Construction and Materials
    CAN/ULC S115 Fire Tests of Firestop Systems Tested to the requirements of UBC 7-2. T
    Tested in accordance with the German Institute of Building Technology standard DIN 4102-1
    Meets the requirements of the British Standard B.S. 476
    ANSI/UL 10B & 10C Fire tests of Door Assemblies, Positive Pressure Fires
    ANSI/UL9 Window Assemblies



    source : http://www.metacaulk.com/index.php/metacaulk-firestopping-products/
  • Diberdayakan oleh Blogger.

    Popular Posts

    WHAT WE DO

    We've been developing corporate tailored services for clients for 30 years.

    CONTACT US

    For enquiries you can contact us in several different ways. Contact details are below.

    Authorized Metacaulk Firestop Jakarta

    • Street :Road Street 00
    • Person :Person
    • Phone :+045 123 755 755
    • Country :POLAND
    • Email :contact@heaven.com

    Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua.

    Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation.